MatWeb, The Online Materials Database

SABIC Innovative Plastics LEXAN 3414R Polycarbonate (Europe)


Subcategory: Polycarbonate; Polymer; Thermoplastic

Close Analogs: Saudi Basic Industries Corporation (SABIC) announced on August 31st, 2007, the completion of its purchase of GE Plastics.

Material Notes:
Information provided by GE Plastics for their European product line. This product is also a part of their North American product line.

Physical PropertiesOriginal ValueComments
Density1.52 g/cc ASTM D 792
Density1.52 g/cc ISO 1183
Filler Content40 % ASTM D 229
Water Absorption0.09 % 24 hours; ASTM D 570
Moisture Absorption at Equilibrium0.1 % (23 C / 50% RH) 1L; ISO 15512
Water Absorption at Saturation0.23 % 23C; ISO 62
Linear Mold Shrinkage0.001 - 0.003 cm/cm Flow; ASTM D 955
Melt Flow4 g/10 min cm3/10min; Melt Volume Rate, MVR at 300C/1.2 kg; ISO 1133

Mechanical Properties
Hardness, Rockwell M93 ISO 2039/2
Hardness, H358/30145 MPa ISO 2039/1
Tensile Strength, Ultimate100 MPa 5 mm/min; ISO 527
Elongation at Break2 % 5 mm/min; ISO 527
Tensile Modulus10 GPa 1 mm/min; ISO 527
Flexural Modulus8.5 GPa 2 mm/min; ISO 178
Flexural Strength145 MPa 2 mm/min; ISO 178
Poisson's Ratio0.39 ASTM D 638
Izod Impact, Notched1 J/cm 23 C; ASTM D 256
Izod Impact, Notched (ISO)8 kJ/m² 80*10*4 +23 C; ISO 180/ 1A
Izod Impact, Unnotched (ISO)30 kJ/m² 80*10*4 +23 C; ISO 180/ 1U
Izod Impact, Unnotched Low Temp (ISO)30 kJ/m² 80*10*4 -30 C; ISO 180/ 1U
Charpy Impact Unnotched2.5 J/cm² 23C, Unnotch Edgew 80*10*4 sp=62; ISO 179/1eU
Charpy Impact, Unnotched Low Temp2.5 J/cm² at -30C, Unnotch Edgew 80*10*4 sp=62; ISO 179/1eU
Charpy Impact, Notched0.9 J/cm² 23 C; ISO 179/2C
Taber Abrasion, mg/1000 Cycles32 CS-17, 1 kg; GE Test

Electrical Properties
Volume ResistivityMin 1e+015 ohm-cm IEC 60093
Surface Resistivity per SquareMin 1e+015 ohm ROA; IEC 60093
Dielectric Constant3.1 1 MHz; IEC 60250
Dielectric Constant3.2 50 Hz; IEC 60250
Dielectric Strength16 kV/mm in oil, 3.2 mm; IEC 60243-1
Dielectric Strength20 kV/mm Short time, 3.2 mm; ASTM D 149
Dielectric Strength20 kV/mm Short time, 1.0 mm; IEC 60243-1
Dielectric Strength25 kV/mm in oil, 1.6 mm; IEC 60243-1
Dielectric Strength33 kV/mm in oil, 0.8 mm; IEC 60243-1
Dissipation Factor0.001 50 Hz; IEC 60250
Dissipation Factor0.01 1 MHz; IEC 60250
Arc Resistance59 sec Tungsten; ASTM D 495
Comparative Tracking Index125 V IEC 60112/3rd
Comparative Tracking Index200 V Stand. Black; IEC 60112/3rd
Comparative Tracking Index225 V Electr Grey; IEC 60112/3rd
Hot Wire Ignition, HWI130 sec UL 746A
High Amp Arc Ignition, HAI6 arcs on surface; UL 746A
High Voltage Arc-Tracking Rate, HVTR6.3 mm/min UL 746A

Thermal Properties
CTE, linear 20°C20 µm/m-°C 23C-80C, flow; ISO 11359-2
Thermal Conductivity0.22 W/m-K ISO 8302
Deflection Temperature at 0.46 MPa (66 psi)144 °C HDT/Be, 0.45MPa Edgew 120*10*4 sp=100mm; ISO 75/Be
Deflection Temperature at 1.8 MPa (264 psi)139 °C HDT/Ae, 1.82 MPa Edgew 120*10*4 sp=100mm; ISO 75/Ae
Deflection Temperature at 1.8 MPa (264 psi)148 °C ASTM D 648
Vicat Softening Point145 °C B/120; ISO 306
Vicat Softening Point147 °C B/50; ISO 306
Vicat Softening Point155 °C A/50; ISO 306
Vicat Softening Point163 °C Rate B; ASTM D 1525
Vicat Softening Point163 °C VST/A/120; DIN 53460
UL RTI, Electrical130 °C UL 746B
UL RTI, Mechanical with Impact125 °C UL 746B
UL RTI, Mechanical without Impact130 °C UL 746B
Flammability, UL94V-0 1.5 mm
Flammability Test1 mm; IEC Needle Flame Test, 10 s , passes at; IEC 60695-2-2
Oxygen Index38 % ISO 4589
Glow Wire Test850 °C Passes at 1 mm; IEC 60695-2-1
Glow Wire Test960 °C Passes at 1.6 mm; IEC 60695-2-1

Descriptive Properties
Ball Pressure Test, 125 C +/- 2 CPASSES IEC 60035-1
Water Absorption, 24 hours, mg9 DIN 53495

 


Copyright 1996-2010 by Automation Creations, Inc.  The information provided by MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from Automation Creations, Inc. No warranty, neither expressed nor implied, is given regarding the accuracy of this information. The user assumes all risk and liability in connection with the use of information from MatWeb.